Resetting the J-200 UV duration countdown timer on your Jacuzzi Hot Tub

Once the duration countdown timer for the CLEARRAY System has reached zero, you will need to reset it, replace the UV bulb and clean the quartz tube. To reset the UV duration countdown timer:

1. Press and hold Jets pump 1 and Cooler (-) at the same time for 3 seconds.
2. Press the Warmer (+) button until the display shows “0.”
3. If the timer has reached “0,” pressing the Jets pump 1 button will reset the timer to 365 days. If the timer is not at “0” pressing the Jets pump 1 button will not reset it.

J-200 UV Timer Reset
Please Note: If the spa power is interrupted, the J-200 UV duration countdown timer is not affected. The number of days remaining is stored in the memory and will continue to countdown once power is regained.
4. If the duration countdown timer is not at “0” and you need to reset it:
a. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
b. Press the Warmer button to scroll to “U.”
c. Press the Jets pump 1 button to switch from “U” to “O3.”
d. Press and hold the Jets pump 1 and Cooler buttons at the same time for 3 seconds.
e. Press the Warmer button to scroll to “O3.”
f. Press the Jets pump 1 button to switch from “O3” to “U.” The timer has been reset to 365 days.

Please note: Only 2012+ J-200 Collection Hot Tubs manufactured by Jacuzzi came with ClearRay UV Water Purification factory installed. To have ClearRay added to an older J-200 Jacuzzi Hot Tub, please contact us for a service appointment. Or, we also take trade in’s for a newer Jacuzzi Hot Tub!

Order Your ClearRay Bulb Here

Download 616, J-200 UV time error code reset instructions here

Download A Copy Of This Here